Input Stringer Definition

Table tbStringerDefinition

PURPOSE

Define stringer location.

Parameters

tbStringerDefinition

Field

Type

Units

Description

Name

text

Stringer line name / number

StartPoint

text

Name of COGO point for start of stringer reference.

EndPoint

text

Name of COGO point that end of member is referenced from.

AutoCn

text

[N|Y] Automatically connect with intersecting lines and points.

RelEndA

text

[Y|N] Moment release member end A (default if blank is N)

RelEndB

text

[Y|N] Moment and axial force release member end B (default if blank is N)

MbrWt

int

Stage to apply stringer weight. Including concrete slab if present.

MbrStf

int

Stage to start using the stiffness properties of the non-composite stringer.

RateFactor

text

Rating Factors

LLDF_ID

text

LRFR only - Live Load Distribution Factor reference to tbExlicitLLDF. Not needed for 2DT (floorbeam) analysis.

Cond

real

Condition factor (phi_c; default = 1.00) – the system factor as defined in AnalysisControls will be added by SteelBridg

Note

Member will be composite if in the live load stage: the slab has stiffness, the member has stiffness, there are shear studs present, and the slab is coupled to the members.