Input Stringer Definition
Table tbStringerDefinition
- PURPOSE
Define stringer location.
Parameters
tbStringerDefinition Field
Type
Units
Description
Name
text
Stringer line name / number
StartPoint
text
Name of COGO point for start of stringer reference.
EndPoint
text
Name of COGO point that end of member is referenced from.
AutoCn
text
[N|Y] Automatically connect with intersecting lines and points.
RelEndA
text
[Y|N] Moment release member end A (default if blank is N)
RelEndB
text
[Y|N] Moment and axial force release member end B (default if blank is N)
MbrWt
int
Stage to apply stringer weight. Including concrete slab if present.
MbrStf
int
Stage to start using the stiffness properties of the non-composite stringer.
RateFactor
text
Rating Factors
LLDF_ID
text
LRFR only - Live Load Distribution Factor reference to tbExlicitLLDF. Not needed for 2DT (floorbeam) analysis.
Cond
real
Condition factor (phi_c; default = 1.00) – the system factor as defined in AnalysisControls will be added by SteelBridg
Note
Member will be composite if in the live load stage: the slab has stiffness, the member has stiffness, there are shear studs present, and the slab is coupled to the members.