Input Truss Member --------------------- **Table** :ref:`tbTrussMember` **PURPOSE** Define truss member locations. **Parameters** .. Include:: ../../tables/tbTrussMember.txt .. note:: If the Local Buckling length is not entered, then no local buckling length check is performed. A warning is issued that no local buckling length check has been done. * If a member's `TCCode` is `T` then that member will only be checked for tension rating, and if it is `C` then that member will only be checked for compression rating. * The `Type` field is [B|T|C|D|V] for code: BOTTOM, TOP, CORD, DIAG, VERT If B,T,or C use Mom rider only loads. If D or V use Shr rider only. Blank=both riders. * The effective length of a member is it's node to node distance times the effective length factor. For calculations that involve the major axis of bending, bending about the local Z axis, the effective length factor MajEffL is used. For bending about the minor axis, the local Y axis, the factor MinEffL is used.

.. image:: ../../image/Effective_Length.png :alt: image/Effective_Length.png