Input Web Haunch Definition =============================== **Table** :ref:`tbWebHaunchDef` **PURPOSE** Automatic haunched member placement is possible when you use the Flange Placement, the Web Placement and Web Haunch Definition tables to define a W1, A3, or A3A type shape for a line member. The haunch calculations are for the web plate depth not the entire shape depth. So you will need to take this into account when setting the depth factors. The flanges and cover plates are added to the 'haunched' web plate to build up the complete section. The haunched section are discrete and computed at sections defined by number of divisions between the start and end of the haunch section. The minimum distance is one (1) foot. **Parameters** .. Include:: ../../tables/tbWebHaunchDef.txt **Example** .. image:: ../../image/haunch_example_A.png :alt: image/haunch_example_A.png .. image:: ../../image/haunch_example_B.png :alt: image/haunch_example_B.png .. image:: ../../image/haunch_example_C.png :alt: image/haunch_example_C.png