Rate Location ================== **Table** :ref:`tbRateLocation` **PURPOSE** The program will automatically use the locations along line members per the `MbrPts` parameter in the :ref:`Analysis Controls` table. These automatically generated locations are used in addition to any explicitly defined locations defined by entries in this table. The `MbrPts` parameter specifies the number of equal spaced locations along the length of a member including the two end points. For example, a `MbrPts` of 5 will create rating locations at the member ends and the three internal third points. For stringers, the engineer can specify additional locations where the program will compute a capacity and a rating value. More then one entry per member line can be specified, and all of the resulting locations will be used. .. note:: This entry is optional and will only apply to stringers. **Parameters** .. Include:: ../../tables/tbRateLocation.txt