Input Hinge Placement

Table tbHingePlacement

PURPOSE

Location of the hinges along a stringer. Hinges must be on a COGO point used either as a member end point or interior-point. An interior point is created by defining a member that spans multiple COGO points using the “AutoCn” option “Y” when placing the stringer. (Input Stringer Definition)

You need to reference an existing hinge defined in the Link-Hinge library. (Input Link Hinge Library)

Parameters

tbHingePlacement

Field

Type

Units

Description

MbrLine

text

Member line name

CogoPt

text

Cogo Point on Member line at hinge.

Hinge

text

Reference Hinge

RateFactor

text

Rating Factors

CxS

real

Condition factor * System factor (phi_c * phi_s) (default = 1.00 if cell is blank or has value of 0.0)

ShearLag

real

Shear lag reduction factor (U = ShearLag) (see AASHTO 6.8.2.2) (default = 1.00 if cell is blank or has value of 0.0)