Input Hinge Placement
Table tbHingePlacement
PURPOSE
Location of the hinges along a stringer. Hinges must be on a COGO point used either as a member end point or interior-point. An interior point is created by defining a member that spans multiple COGO points using the “AutoCn” option “Y” when placing the stringer. (Input Stringer Definition)
You need to reference an existing hinge defined in the Link-Hinge library. (Input Link Hinge Library)
Parameters
Field |
Type |
Units |
Description |
|---|---|---|---|
MbrLine |
text |
Member line name |
|
CogoPt |
text |
Cogo Point on Member line at hinge. |
|
Hinge |
text |
Reference Hinge |
|
RateFactor |
text |
Rating Factors |
|
CxS |
real |
Condition factor * System factor (phi_c * phi_s) (default = 1.00 if cell is blank or has value of 0.0) |
|
ShearLag |
real |
Shear lag reduction factor (U = ShearLag) (see AASHTO 6.8.2.2) (default = 1.00 if cell is blank or has value of 0.0) |