Input Flange Placement

Table tbFlangeDef

PURPOSE

Instead of using a shape from the shapes library, a stringer member can be defined by referencing plates from the plate library for web and flanges. This is similar to using the built up W1 (Input Built-up Shape Types - W1 ) shape but you have more freedom to make changes in web and flange dimensions along the length of a stringer.

Do not use this entry with Shape Placement placement, but you can include Cover Plates

Parameters

tbFlangeDef

Field

Type

Units

Description

MbrLine

text

Member line name

StartDist

real

FET

Distance from start of member line

EndDist

real

FET

Distance from start of member line to end of this shape placement. (Entry optional)

Shape

text

Plate from plate library or an angle for standard shapes library (ONLY single angles allowed from std shapes)

Tp_Bt

chr

[ |T|B] Flange location (T=Top, B=Bottom, Blank=Both)

NegFArea

real

IN2

Area of fastener holes (sqi) in tension flange

NegHArea

real

IN2

Area of hand holes (sqi)

Code

text

If shape is an angle, enter A3 or A3A for angle orientation for built-up section type (default is type A3)