Input Flange Placement
Table tbFlangeDef
- PURPOSE
Instead of using a shape from the shapes library, a stringer member can be defined by referencing plates from the plate library for web and flanges. This is similar to using the built up W1 (Input Built-up Shape Types - W1 ) shape but you have more freedom to make changes in web and flange dimensions along the length of a stringer.
Do not use this entry with Shape Placement placement, but you can include Cover Plates
Parameters
tbFlangeDef Field
Type
Units
Description
MbrLine
text
Member line name
StartDist
real
FET
Distance from start of member line
EndDist
real
FET
Distance from start of member line to end of this shape placement. (Entry optional)
Shape
text
Plate from plate library or an angle for standard shapes library (ONLY single angles allowed from std shapes)
Tp_Bt
chr
[ |T|B] Flange location (T=Top, B=Bottom, Blank=Both)
NegFArea
real
IN2
Area of fastener holes (sqi) in tension flange
NegHArea
real
IN2
Area of hand holes (sqi)
Code
text